Improve Failure Detection and Optimize ProtectionIn the ever-evolving field of protective relay technology, an engineerтАЩs personal preference and professional judgment are as important to power system protection as the physical relays used to detect and isolate abnormal conditions.

Invaluable Insights from an Experienced Expert
Protective Relay Principles focuses on probable power system failure modes and the important characteristics of the protective relays used to detect these postulated failures. The book presents useful new concepts in a way that is easier to understand because they are equally relevant to older, electromechanical and solid-state relays, and newer, more versatile microprocessor-based relays. It introduces the applications, considerations, and setting philosophies used in transmission-line, distribution-line, and substation applications, covering concepts associated with general system operations and fault detection. Topics include relay load limits, cold load pickup, voltage recovery, and arc flash. The author also delves into the philosophies that engineers employ in both urban and rural areas, with a detailed consideration of setpoint function.

Analysis of Key Concepts That Are Usually Just Glossed Over
This versatile text is ideal for new engineers to use as a tutorial before they open the instruction manuals that accompany multi-function microprocessor-based relays. Guiding readers through the transient loading conditions that can result in relay misoperation, the author elaborates on concepts that are not generally discussed, but can be very helpful in specific applications. Readers will come away with an excellent grasp of important design considerations for working with overcurrent, over- and undervoltage, impedance, distance, and differential type relay functions, either individually or in combination. Also useful for students as a textbook, this book includes practical examples for many applications, and offers guidance for more unusual ones.

рдореВрд▓реНрдпрд╛рдЩреНрдХрди рд░ рд╕рдореАрдХреНрд╖рд╛рд╣рд░реВ

рек.рем
рен рд╕рдореАрдХреНрд╖рд╛рд╣рд░реВ

рд▓реЗрдЦрдХрдХреЛ рдмрд╛рд░реЗрдорд╛

Anthony Sleva is president of Sleva Associates, an electrical consulting and training company. He is a registered Professional Engineer with a BSEE degree from Pennsylvania State University. During his career, he has designed electrical systems for nuclear generating stations; designed 500-230 KV, 230-69 KV, 138-12 KV and 69-12 KV substations; provided technical support to power dispatchers, system operators and plant operators; and developed technical training programs for technicians, drafters, designers and technical clerks. Mr. Sleva specializes in the analysis of power system events that cause the loss of customer load and/or the initiation of emergency load control procedures as well as events that may have been caused by incorrect protective relay actuations.

рдпреЛ рдЗ-рдкреБрд╕реНрддрдХрдХреЛ рдореВрд▓реНрдпрд╛рдЩреНрдХрди рдЧрд░реНрдиреБрд╣реЛрд╕реН

рд╣рд╛рдореАрд▓рд╛рдИ рдЖрдлреНрдиреЛ рдзрд╛рд░рдгрд╛ рдмрддрд╛рдЙрдиреБрд╣реЛрд╕реНред

рдЬрд╛рдирдХрд╛рд░реА рдкрдвреНрджреИ

рд╕реНрдорд╛рд░реНрдЯрдлреЛрди рддрдерд╛ рдЯреНрдпрд╛рдмрд▓реЗрдЯрд╣рд░реВ
Android рд░ iPad/iPhone рдХрд╛ рд▓рд╛рдЧрд┐┬аGoogle Play рдХрд┐рддрд╛рдм рдПрдк рдХреЛ рдЗрдиреНрд╕реНрдЯрд▓ рдЧрд░реНрдиреБрд╣реЛрд╕реНред рдпреЛ рддрдкрд╛рдИрдВрдХреЛ рдЦрд╛рддрд╛рд╕реЕрдВрдЧ рд╕реНрд╡рддрдГ рд╕рд┐рдВрдХ рд╣реБрдиреНрдЫ рд░ рддрдкрд╛рдИрдВ рдЕрдирд▓рд╛рдЗрди рд╡рд╛ рдЕрдлрд▓рд╛рдЗрди рдЬрд╣рд╛рдБ рднрдП рдкрдирд┐┬ардЕрдзреНрдпрдпрди рдЧрд░реНрди рджрд┐рдиреНрдЫред
рд▓реНрдпрд╛рдкрдЯрдк рддрдерд╛ рдХрдореНрдкреНрдпреБрдЯрд░рд╣рд░реВ
рддрдкрд╛рдИрдВ Google Play рдорд╛ рдЦрд░рд┐рдж рдЧрд░рд┐рдПрдХреЛ рдЕрдбрд┐рдпреЛрдмреБрдХ рдЖрдлреНрдиреЛ рдХрдореНрдкреНрдпреБрдЯрд░рдХреЛ рд╡реЗрдм рдмреНрд░рд╛рдЙрдЬрд░ рдкреНрд░рдпреЛрдЧ рдЧрд░реЗрд░ рд╕реБрдиреНрди рд╕рдХреНрдиреБрд╣реБрдиреНрдЫред
eReaders рд░ рдЕрдиреНрдп рдЙрдкрдХрд░рдгрд╣рд░реВ
Kobo eReaders рдЬрд╕реНрддрд╛ e-ink рдбрд┐рднрд╛рдЗрд╕рд╣рд░реВрдорд╛ рдлрд╛рдЗрд▓ рдкрдвреНрди рддрдкрд╛рдИрдВрд▓реЗ рдлрд╛рдЗрд▓ рдбрд╛рдЙрдирд▓реЛрдб рдЧрд░реЗрд░ рдЙрдХреНрдд рдлрд╛рдЗрд▓ рдЖрдлреНрдиреЛ рдбрд┐рднрд╛рдЗрд╕рдорд╛ рдЯреНрд░рд╛рдиреНрд╕реНрдлрд░ рдЧрд░реНрдиреБ рдкрд░реНрдиреЗ рд╣реБрдиреНрдЫред рддреА рдлрд╛рдЗрд▓рд╣рд░реВ рдкрдвреНрди рдорд┐рд▓реНрдиреЗ рдЗрдмреБрдХ рд░рд┐рдбрд░рд╣рд░реВрдорд╛ рддреА рдлрд╛рдЗрд▓рд╣рд░реВ рдЯреНрд░рд╛рдиреНрд╕реНрдлрд░ рдЧрд░реНрдиреЗрд╕рдореНрдмрдиреНрдзреА рд╡рд┐рд╕реНрддреГрдд рдирд┐рд░реНрджреЗрд╢рдирд╣рд░реВ рдкреНрд░рд╛рдкреНрдд рдЧрд░реНрди рдорджреНрджрдд рдХреЗрдиреНрджреНрд░ рдорд╛ рдЬрд╛рдиреБрд╣реЛрд╕реНред